Filter Results By:

Products

Applications

Manufacturers

Showing results: 91 - 96 of 96 items found.

  • Milliohm Meter

    Tenmars Electronics Co., Ltd.

    *3-1/2 digit LCD display with maximum reading of 2000.*Low battery indication.*Zero adjustment: External zero adjustment control.*Very low impedance measurement, four-wire type, one pair insulated clip.*Wide measurement range 1 milliohm to 20k Ohm in six switchable steps.*Fuse protection: 2 Amp/250Volt (5mm x 20mm), fast minimum interrupt ratings 1500A.*Function keys: D-H switch lockup readings for LCD display.*Dimensions: 160mm (L) x 100mm (W) x 52mm (D)*Weight: 700g approx.

  • Audio Multimeter

    AMM-1 - D'Amore Engineering llc

    The purpose of this tool is to enable the user to: Measure True Amplifier Power output into any load reactive or resistive Measure Common DC voltages Measure DC voltage drops during quick transients on cable runs or battery / charging systems Measure Impedance of speakers at any power or frequency from 20Hz - 1kHz (box rise) Measure Phase Difference between Voltage and Current into reactive loads (Power Factor) Find Tuning Frequency of subwoofer enclosures Tune subwoofer enclosures for maximum power transfer Measure AC Volts (amplifier output) Measure AC Amps (amplifier output)

  • Radio Vector Tester

    Wuhan Sunma Technology Co., Ltd.

    Radio & Vector Network Analyzer adopts the advanced digital and RF combination design technology, fundamental wave frequency mixing technology, digital IF processing technology, intelligent power management technology, etc. It comes with features of high precision, small size, light weight, battery power, can measure SWR, Return Loss, Cable Loss, Impedance, DTF, etc, is used to the field test of cable, feeder, and the reflection parameters test of RF components in science and teaching. SunmaFiber provide all kinds of CATV meters, such as Signal Level Meter, QAM Analyzer, Spectrum Analyzer, DVB/DVC/DVT Analyzer and other TV testers.

  • Cable Tracer and Digital Multimeter

    187 MCT - Standard Electric Works Co., Ltd

    Lan Cable Tester● Designed for RJ45/RJ11 modular cables, 10/100 base-T cable and Token Ring cable etc.● The LAN cable tester can verify cable continuity, open, circuit and miss-wired. ● The remote receiving unit is available for installed cables far away either on the wall plates or on the patch panels.● Auto and manual scan function.● Ground wire test.● Display : LED indication for wire status.Digital Multimeter● 4000 counts LCD.● Full automatic measurement. Voltage measurement. Resistor measurement.● Range change function.● Select function.● Data Hold function.● Continuity check.● Diode measurement.● Low battery indication.● Input impedance:10MΩ.

  • CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel

    40-200-008 - Pickering Interfaces Ltd.

    This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

Get Help